======================================= :mod:`leica_tcr_1205` -- Leica TCR 1205 ======================================= .. moduleauthor:: Stefano Costa .. moduleauthor:: Luca Bianconi Description ----------- This is a quite recent total station. Data were provided by Joseph Reeves of Oxford Archaeology. Connection ---------- :Baudrate: higher than 19200 :Bytesize: 8 :StopBits: 1 :Parity: None Data format ----------- The data format is ASCII, quite simple. The only thing to note is that data dumps contain both relative and absolute measures. :ref:`if_leica_tcr_1205` ===================================== :mod:`nikon_npl_322plus` -- Nikon NPL-322+ ===================================== .. moduleauthor:: Sebastian Gutwein .. versionadded:: 0.6 Description ----------- Tested on a NPL 322+ but should also work with other NPL 322 models. Connection ---------- Tested using a serial cable with an usb adaptor. :Baudrate: 9600 :Bytesize: 8 :StopBits: 1 :Parity: None Data format ----------- The data format is in ASCII format. :ref:`if_nikon_raw` ===================================== :mod:`nikon_npl_350` -- Nikon NPL-350 ===================================== .. moduleauthor:: Stefano Costa Description ----------- Connection ---------- Even the brute method ``cat /dev/ttyS0 > file`` creates an ASCII file without any problem, so probably the default parameters for the serial port are OK. :Baudrate: higher than 19200 :Bytesize: 8 :StopBits: 1 :Parity: None Data format ----------- The data format is in ASCII format. :ref:`if_nikon_raw` ======================================= :mod:`trimble` -- Trimble ======================================= .. moduleauthor:: Stefano Costa Description ----------- Connection ---------- :Baudrate: 9600 :Bytesize: 8 :StopBits: 1 :Parity: None Data format ----------- The data format is ASCII, quite simple. :ref:`if_trimble_are` ======================================= :mod:`zeiss_elta_r55` -- Zeiss Elta R55 ======================================= .. moduleauthor:: Stefano Costa Description ----------- This is a quite old device, in use at the University of Siena. The first steps in TOPS development were achieved with it. Connection ---------- The hardware interface consists of a serial RS232 cable, that works also with a common :term:`serial-USB adapter` . :Baudrate: 9600 :Bytesize: 7 :Parity: None Output formats -------------- The Zeiss Elta R55 total station can output data in four different formats, only one of which is currently supported: - :ref:`if_zeiss_rec_500` - Zeiss R-4 - Zeiss R-5 - Zeiss R-E